Product Identification
Product ID:AURASPERSE PERMANENT CARMINE W-3160
MSDS Date:11/15/1988
FSC:6850
NIIN:00N018998
MSDS Number: BLGHJ
Responsible Party
SOLON, OH 44139
US
Emergency Phone: 216-292-9200
Info Phone: 216-292-9200
Cage: 23036
Contractor
Telephone: 216-292-9200
Cage: 23036
Ingredients
2-BUTOXYETHANOL
CAS: 111-76-2
RTECS: KJ8575000
Fraction By Weight: 1 - 7%
OSHA PEL S, 50 PPM
ACGIH TLV: S, 25 PPM; 9293
SURFACTANT
Fraction By Weight: 4%
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:CAUSES IRRIT & POSSIBLE CORNEAL
INJURY. SKIN:PRLNGD/RPTD CONT MAY CAUSE REDDENING, SWELLING &
POSSIBLE DMG TO SKIN. TOX AMTS MAY BE ABSORBED THRU SKIN. SIGNS &
SYMP OF TOX BY THIS ROUTE SAME AS FO R INGEST. INHAL:INHAL OF HIGH
CONC CAUSES IRRIT OF RESP TRACT. SYMP INCLUDE HDCH, DIZZ, NAUS,
VOMIT(SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: & MALAISE. INGEST:MAY CAUSE HDCH,
DIZZ, INCOORDINATION, NAUS, VOMIT, DIARRHEA, GENERAL WEAKNESS, RED
BLOOD CELL HEMOLYSIS, POSSIBLE LIVER & KIDNEY DMG. HARMFUL IF LRG
AMTS ARE SWALLOWED. ANI MAL STUDIES CLEARLY DEMONSTRATED
DOSE-RELATED ADVERSE EFTS ON CNS, HEMATOPOIETIC TISS, BLOOD,
KIDNEYS (SEE SUPP DATA)
Medical Cond Aggravated by Exposure:MAY ADVERSELY AFFECT EXISTING
MEDICAL CONDITIONS SUCH AS EYE, SKIN, RESPIRATORY, BLOOD, LIVER
AND/OR KIDNEY AILMENTS.
First Aid
First Aid:EYE & SKIN: IMMEDIATELY FLUSH EYES WITH PLENTY OF WATER FOR
AT LEAST 15 MINUTES. CALL MD. FLUSH SKIN WITH WATER. INHAL: REMOVE
TO FRESH AIR. IF BREATHING IS DIFFICULT, GIVE OXYGEN. CALL MD.
INGEST: IF SWALLOWED, INDUCE VOMITING IMMEDIATELYAS DIRECTED BY
MEDICAL PERSONNEL.
Fire Fighting
Flash Point:NOT AVAILABLE
Extinguishing Media:USE WATER, CO2 OR FOAM.
Fire Fighting Procedures:NONE EXPECTED.
Unusual Fire/Explosion Hazard:NOT A FIRE OR EXPLOSION HAZARD.
Accidental Release
Spill Release Procedures:CONTAIN SPILLAGE, SOAK UP W/INERT ABSORBENT &
SCOOP INTO CNTNR FOR DISP. NOTIFICATION OF THE NATIONAL RESPONSE
CENTER (800-424-8802) MAY BE REQUIRED. REFER TO EPA, DOT AND
APPLICABLE STATE AND LOCAL R EGS FOR CURRENT RESPONSE INFORMATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AWAY FROM FOOD AND FEED PRODUCTS.
KEEP CONTAINER CLOSED. PROTECT FROM FREEZING. PROTECT FROM
FREEZING. AVOID BRTHG VAPS OR MIST.
Other Precautions:AVOID CONT W/EYES, SKIN & CLTHG. USE W/ADEQ VENT.
GOOD STORAGE STABILITY W/NORMAL CNDTNS. ANY SOFT SETTLING REMOVED
BY STIRRING. WATER LOST BY EVAP CAN ADVERSELY AFFECT VISCOSITY,
DISPERSABILITY & OTH ER PHYSICAL PROPERTIES.
Exposure Controls
Respiratory Protection:A NIOSH/MSHA APPROVED RESPIRATOR AS NECESSARY.
Ventilation:GENERAL; LOCAL EXHAUST AS NECESSARY TO CONTROL VAPORS
AND/OR MISTS.
Protective Gloves:RUBBER OR NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
PH: 9.2-10.2. EFTS OF OVEREXP: AND LIVER, ASSOC W/ADMINISTRATION OF
ETHYLENE GLYCOL MONOBUTYL ETHER (EGBE) AND ETHYLENE GLYCOL
MONOBUTYL ETHER ACETATE (EGBEA) (EXTRACTED FROM DHHS (NIOSH)) PUB
90-118 . WASTE DISP METH: DISP SELECTED.SOME WASTE MATERIALS ARE
AMENABLE TO RECYCLE/REUSE.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:<17.5@ 20C
Spec Gravity:1.08 (TYPICAL)
pH:SUPDAT
Evaporation Rate & Reference:SLIGHTLY SLOWER THAN H2O
Solubility in Water:60% (TYPICAL)
Appearance and Odor:RED LIQUID; SLIGHT AMMONIACAL ODOR; PH 9.7
(TYPICAL).
Stability
Stability Indicator/Materials to Avoid:YES
NONE EXPECTED.
Stability Condition to Avoid:NONE EXPECTED.
Hazardous Decomposition Products:NONE EXPECTED.
Disposal
Waste Disposal Methods:FED, ST & LOC DISP LAWS & REGS WILL DETERMINE
PROPER WASTE DISP PROC. ALL WASTE MATLS SHOULD BE REVIEWED TO
DETERMINE APPLIC HAZARDS (TESTING MAY BE NEC). DISP REQ ARE
DEPENDENT ON HAZARD CLASSIFICATI ON & WILL VARY BY LOCATION & TYPE
OF (SUPP DATA)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.